Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Orthop Relat Res ; (372): 85-94, 2000 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10738418

RESUMO

Carpal tunnel syndrome, Colles' fracture, and osteoarthritis of the basilar joint of the thumb are only three of the many upper extremity conditions that preferentially affect women. With more and more women entering the workplace, these conditions become more disruptive of patients' lifestyles and even may be increasing in incidence. Orthopaedic surgeons traditionally have focused on the surgical treatment of patients with these conditions, but it is becoming increasingly clear that surgeons also must focus on delineating pathophysiology to better identify those individuals at risk and help prevent these potentially disabling disorders.


Assuntos
Síndrome do Túnel Carpal , Fratura de Colles , Osteoartrite , Síndrome do Túnel Carpal/diagnóstico , Síndrome do Túnel Carpal/terapia , Fratura de Colles/diagnóstico , Fratura de Colles/terapia , Transtornos Traumáticos Cumulativos/diagnóstico , Transtornos Traumáticos Cumulativos/terapia , Feminino , Humanos , Osteoartrite/diagnóstico , Osteoartrite/terapia , Fatores de Risco , Fatores Sexuais , Polegar
2.
Tech Hand Up Extrem Surg ; 2(1): 50-5, 1998 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16609484
3.
J Hand Surg Br ; 21(1): 99-102, 1996 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-8676039

RESUMO

We have investigated five devices suitable for scaphoid fixation (ASIF 2.7 mm and 3.5 mm cannulated screws, Herbert, Herbert-Whipple, and Howmedica Universal Compression Screw). The biomechanical properties tested were compression and resistance to cantilever bending. There was no statistically significant difference in compression between devices. There were significant differences in resistance to cantilever bending, with the Howmedica screw being strongest in both failure mode and in ultimate failure strength.


Assuntos
Parafusos Ósseos , Ossos do Carpo/lesões , Ossos do Carpo/cirurgia , Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/cirurgia , Humanos , Estresse Mecânico
4.
J Hand Surg Am ; 20(4): 650-6, 1995 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-7594296

RESUMO

This study was designed to investigate several biomechanical parameters involved in repair of extensor tendons in Zone IV (over the proximal phalanx). Typical suture techniques over the proximal phalanx did not shorten the tendon significantly nor was there significant loss of flexion at the metacarpophalangeal or proximal interphalangeal joints. The Kleinert modification of the Bunnell technique and modified Kessler technique seemed to be the strongest and provided evidence that dynamic or active range of motion, under controlled conditions and in short arcs, might be physiologically tolerated by repaired tendons.


Assuntos
Técnicas de Sutura , Tendões/cirurgia , Fenômenos Biomecânicos , Cadáver , Articulações dos Dedos , Dedos , Humanos , Articulação Metacarpofalângica , Polipropilenos , Amplitude de Movimento Articular , Tendões/fisiologia
6.
J Hand Surg Am ; 17(6): 1117-23, 1992 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-1430953

RESUMO

Despite their ease of exposure, extensor tendons can be difficult to handle and suture well. Compared with flexor repair, little is known about the various factors that affect the suturing of extensor tendons. The present study was designed to investigate several biomechanical parameters involved in extensor repair. All techniques studied shortened the tendon considerably and produced significant losses of flexion at the metacarpophalangeal and proximal interphalangeal joints. In addition, repairs achieved with all suture techniques were considerably weaker than those achieved when comparable techniques were used on flexor tendons. However, the Kleinert modification of the Bunnell technique provided the strongest sutures in extensor tendons, produced no gapping, caused the least worrisome loss of metacarpophalangeal and proximal interphalangeal flexion, and best approximated the results found in an idealized tendon-shortening model.


Assuntos
Dedos , Mãos , Técnicas de Sutura/normas , Tendões/cirurgia , Fenômenos Biomecânicos , Cadáver , Estudos de Avaliação como Assunto , Humanos , Amplitude de Movimento Articular , Tendões/anatomia & histologia , Tendões/fisiologia , Resistência à Tração
7.
J Hand Surg Am ; 17(2): 272-7, 1992 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-1564273

RESUMO

The use of dynamic extension splinting in the rehabilitation of extensor tendon injuries is gaining interest because of its apparent ability to improve clinical results. With such splinting, the extensor musculature is theoretically quiescent during both active flexion and rubber band-mediated extension; the gliding produced thereby decreases adhesion formation. Our initial intent was to perform electromyographic studies on volunteers in dynamic extension splinting to test this electrophysiologic principle. It was found, however, that only 16% of normal volunteers have quiescent extensor digitorum communis muscle activity within the dynamic extension splint typically used in this type of rehabilitation. A second splint was developed with a dorsal hood to keep the metacarpophalangeal joints in approximately 15 degrees of flexion. In this splint, 18 of 19 volunteers (95%) showed no extensor activity. The explanation for this phenomenon is not yet clear, but it shows that splint design plays a more significant role than previously expected. The expected electrophysiologic principle of dynamic extension splinting for extensor tendon injuries has been validated, but only in a splint design that is not commonly used.


Assuntos
Dedos/fisiologia , Músculos/fisiologia , Contenções , Eletromiografia , Humanos , Movimento
8.
J Hand Surg Am ; 15(6): 961-6, 1990 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-2269792

RESUMO

A retrospective analysis was done in 62 patients with 101 digits having extensor tendon injury. Quality of outcome and parameters that might influence outcome were evaluated. The majority of patients were treated with conventional static splinting. Sixty percent of all fingers sustained an associated injury (fracture, dislocation, joint capsule or flexor tendon damage). Patients without associated injuries achieved 64% good/excellent results, and total active motion of 212 degrees. This difference was statistically significant (p less than 0.05). Distal zones (1 to 4) had a significantly poorer result than more proximal zones (5 to 8). The percentage of fingers losing flexion was greater than the percentage of fingers losing extension. In addition, the average degree loss of flexion was greater than the average degree loss of extension. This would seem to indicate that loss of flexion may be a more significant complication from extensor tendon injury than previously thought.


Assuntos
Traumatismos dos Dedos/cirurgia , Traumatismos dos Tendões/cirurgia , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Feminino , Traumatismos dos Dedos/complicações , Traumatismos dos Dedos/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Movimento , Prognóstico , Estudos Retrospectivos , Contenções , Traumatismos dos Tendões/complicações , Traumatismos dos Tendões/fisiopatologia , Fatores de Tempo
9.
J Hand Surg Am ; 15(5): 748-50, 1990 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-2229972

RESUMO

A retrospective study of 235 patients with 338 primary trigger fingers determined the efficacy and safety of steroid injection. Initial treatment consisted of one to three injections of corticosteroid mixed with local anesthetic. Those fingers that failed injection therapy had conventional release of the first annular pulley. Seventy-seven percent of all fingers showed resolution or improvement; 49% after a single injection, 23% after two injections, and 5% after three injections.


Assuntos
Esteroides Clorados/uso terapêutico , Tenossinovite/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Injeções Intradérmicas , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Esteroides Clorados/administração & dosagem
10.
Bull Hosp Jt Dis Orthop Inst ; 46(1): 1-8, 1986.
Artigo em Inglês | MEDLINE | ID: mdl-3015291

RESUMO

Thirteen patients (14 hips) underwent revision from conventional cemented total hip arthroplasty to uncemented acetabular threaded screw-in components and cementless femoral press-fit stems by means of the Autophor, Biofit, and Ti-Thread designs. The patients suffered from all forms of primary hip disease except rheumatoid arthritis; their average age was 34 years. The average preoperative Harris hip score was 39.4; the average postoperative score was 71.2 at six months, 90.6 at one year, and 91.6 at two years. Complications included two femoral shaft fractures, one femoral nerve palsy, and one dislocation. No signs have been observed of loosening or migration as of an early (6-24 months) follow-up.


Assuntos
Acetábulo/cirurgia , Prótese de Quadril , Adulto , Idoso , Feminino , Seguimentos , Prótese de Quadril/efeitos adversos , Prótese de Quadril/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Reoperação , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...